Water Treatment & Quality

Hospital water quality monitoring, treatment system status, and test records

Residual chlorine below acceptable level (0.08 mg/L — target 0.2–0.5). Increase chlorination dosing immediately.

Tests Passed

5

Failed / Warning

2

Last Tested

23 Jun 2026

Test Frequency

Daily sampling

Today's Water Quality Test — 23 Jun 2026

ParameterValueUnitAcceptable RangeStatus
pH7.36.5–8.5
Pass
Total Dissolved Solids (TDS)210mg/L< 500
Pass
Total Hardness180mg/L CaCO₃< 300
Pass
Residual Chlorine0.08mg/L0.2–0.5 (distribution)
Fail
Total Coliform0CFU/100 mL0
Pass
E. coli0CFU/100 mL0
Pass
Turbidity0.8NTU< 1.0
Warning

Treatment Systems

Reverse Osmosis (RO) Plant

Capacity: 10,000 L/day · Last service: 01 Jun 2026 · Next: 01 Sep 2026

Operational

UV Disinfection Unit

Capacity: 5,000 L/day · Last service: 15 May 2026 · Next: 15 Aug 2026

Operational

Dialysis Water System (AAMI standard)

Capacity: Dedicated · Last service: 01 Jun 2026 · Next: 01 Jul 2026

Service Due